Early Warning Is In The Air For Effective Thermal Management



Rajesh Nair  |   ED Online ID #19332  |   July 24, 2008

Article Rating: Not Rated

For today’s makers of high-reliability equipment, increased performance requirements have meant packing more and more hardware onto boards and stuffing higher-density boards into shrinking chassis.

As a result, the power density (power dissipated per unit area) of electronic products, measured by the ability to dissipate heat, has skyrocketed, increasing by a factor of 20 to 50 in the last few decades. More and more, hot new products mean hotter chips and higher internal temperatures. However, the maximum temperatures that components can withstand haven’t changed significantly recently.

Managing this heat is essential because more heat means lower performance, premature shutdown, and even system failure. High power levels and high packaging density require fans with higher pressure and airflow performance to push air through the product. This also means increasing power consumption for fans. How can an equipment maker provide the performance its market demands and still keep things cool? One approach is to use an airflow sensor to monitor hot spots.

TOO LITTLE, TOO LATE
Sensors used on circuit boards typically measure only the board or ambient temperature in a product. But by the time a component overheats and the sensor detects a high temperature, there is a delay due to the thermal inertia of the board and chassis. High heat density and slow response due to high thermal inertia can be a fatal combination.

Because airflow does the cooling, impending temperature rise can be much better predicted, much earlier, by monitoring airflow across the component or board area. A good solution would be to use a small sensor capable of airflow measurement at the board/component level. Such a device can monitor airflow and warn the system of a future temperature rise as the flow drops. One such device is the Accusense F600 pulse-airflow sensor (Fig. 1). This board-mounted sensor is just 0.5 by 1 in. In addition to measuring air temperature from 20°C to 60°C, it directly measures airflow. Velocity measurement range is 0.15 to 5 m/s, or 30 to 1000 fpm, with an absolute accuracy of ±20% of the reading with a repeatability of better than 5%.

With several sensors placed at critical locations on a board, these additional airflow data points help complete a picture of temperature rise before it becomes a serious problem, allowing the machine’s hardware and software to respond appropriately. For electronic products with both high power density and high expectations of availability, real-time air temperature and air velocity measurement can spell the difference between simply promising reliability and consistently delivering it.

PROTECT THE EQUIPMENT, PROTECT THE USER
For many applications, effective early warning may be enough to keep the product working at an acceptable level of service. By reducing power to certain applications long enough to cool their chips, machines can stay in service. In addition, temperature rises caught early can clue operators in on some predictable trouble spots, such as a fan failure, clogged air filters, or clogged inlets. When such preventive measures fail, knowing when critical levels are approaching means an opportunity for graceful shutdown, preventing data loss, lengthy reboot procedures, and unhappy users. But providers of critical services such as communications and IT systems don’t have the option of shutting down.

For these situations, the early warning via the addition of airflow information does not mean early termination, but more effective thermal management. Maintenance programs can rely on receiving additional data points, such as when air filter replacement or other maintenance is due. Airflow blockages can generate alarms and receive immediate service, changing the situation from an emergency repair to a preventive maintenance call.

And, conserving cooling power doesn’t mean just saving electricity. It means keeping additional power on tap at all times, staying up and running to provide critical services. Most importantly, for effective thermal management, componentlevel airflow sensors can provide the data necessary to manage the array of fans and fan boards found in this type of highpower equipment.

POWER, TEMPERATURE, AND FANS
More than any other single factor, knowing when to increase fan power and when it can be safely decreased is critical for managing both temperature and power consumption. Hot chips rely on fans for cooling, and fans rely on accurate temperature readings.

But a fan’s ability to cool a device isn’t linear. From heat transfer equations, the temperature rise of a device is inversely proportional to the airflow over it. At low airflow levels, temperature increases can be significant. As airflow increases beyond approximately 600 fpm, though, the reduction in temperature rise is minimal in relation to the rise in airflow.

The energy consumption by a fan is proportional to the cube of fan speed (N3). Therefore, as the airflow is increased for lower device temperature rise, the power consumed by fans can be significantly high, leading to negative net returns.

For example, in a sample case, an increase in airflow from 400 to 800 fpm results in a temperature drop of only 5°C with a required power increase of approximately 85 W (Fig. 2). The clear challenge is to operate at an optimum airflow range while keeping the necessary fan power within budget. This requires measurement of airflow. Air velocity becomes equally critical as air temperature in the efficient cooling of circuit boards and in controlling fan power.

Continue on Page 2




<-- prev. page     [1] 2     next page -->

Reprints     Printer-Friendly    Email this Article    RSS        Font Size     What's This?


  • User Advisory Group To Guide Open Verification Methodology’s Evolution
  • DDR3 and DDR2 Memory IP Bolsters SoC Designs
  • PCB Tools Cross-Probe Between Layout And Schematic
  • Constraint-Driven Flow Targets PCB High-Density Interconnects
  • Cadence Abandons Its Bid To Buy Mentor Graphics
  • Model Extractor For CMOS Sports Improved RF/DC Parameters
  • 45-nm Via-Programmable ASICs Add High-Speed I/O Transceivers To Feature Mix
  • Get Ready For NIWeek
    1) Low-Dropout (LDO) Linear Regulators
    (873 views today)
    2) DNA In Your Gadgets?
    (688 views today)
    3) SDR Transforms Amateur Radio
    (563 views today)
    4) Build A Smart Battery Charger Using A Single-Transistor Circuit
    (260 views today)
    5) Easily Convert Decimal Numbers To Their Binary And BCD Formats
    (198 views today)
    ALL TOP 20







    POST YOUR COMMENTS HERE

    Name:

    Email:
    Rate this article:

     less useful more useful 
    1
    2
    3
    4
    5
    Your Comments:

    Enter the text from the image below




    Please refresh the page if you have trouble reading this text.
     
     

    PartFinder

    Find real-time pricing, stock status, same-day/next-day shipping options and more. Brought to you by Digi-Key. Go to PartFinder.    
    GlobalSpec

    PART SEARCH :
    Powered by: GlobalSpec - The Engineering Search Engine
    Sponsored Links

    Electronic Design Europe Electronic Design China EEPN Power Electronics Auto Electronics Microwaves & RF RF Design
    Schematics Find Power Products Military Electronics Featured Vendors EE Events Free Design Resources